. 2014 Aug 23;252(10):1679–1686. doi: 10.1007/s00417-014-2776-2

Table 2.

Comparison of visual and refractive results at 1 year with baseline values in mixed astigmatism showing the main results of the investigation

Visual and refractive results — mixed astigmatism
Mean ± standard deviation
Variable Wavelight Allegretto Eye-Q Schwind Amaris 750S
preop postop p value* preop postop p value*
UDVA 0.25 ± 0.14 (0.03 to 0.60) 0.77 ± 0.20 (0.20 to 1.00) <0.001 0.24 ± 0.12 (0.02 to 0.60) 0.80 ± 0.21 (0.05 to 1.00) <0.001
CDVA 0.74 ± 0.22 (0.15 to 1.00) 0.82 ± 0.21 (0.20 to 1.00) 0.04 0.77 ± 0.20 (0.04 to 0.95) 0.85 ± 0.21 (0.10 to 1.00) 0.004
sphere (D) 2.72 ± 1.79 (0.25 to 7.00) 0.19 ± 0.52 (−1.50 to +1.50) <0.001 3.11 ± 1.57 (0.50 to 7.50) 0.28 ± 0.45 (−0.75 to 1.00) <0.001
cylinder (D) −3.84 ± 1.21 (−6.50 to −2.00) −0.85 ± 0.41 (−2.00 to 0.00) <0.001 −3.66 ± 1.16 (−7.00 to −2.00) −0.58 ± 0.38 (−1.50 to 0.00) <0.001

UDVA = uncorrected distance visual acuity (decimal)

CDVA = corrected distance visual acuity (decimal)

D = diopter

*2-sample z-test assuming unequal variances