Flow, conductance, and systemic blood pressure responses to 1.0 mM nitrite infusion into one hind limb of anesthetized sheep at different levels of oxygenation

Flow, ml/min
Conductance, ml·min−1·mmHg−1
[Nitrite], mM Inspired O2, % n Ipsilateral Contralateral Ipsilateral Contralateral Blood Pressure, mmHg Flow Ratio
Pre 50 8 82.3 ± 5.9 80.1 ± 4.5 0.61 ± 0.04 0.60 ± 0.05 136.0 ± 6.2 1.05 ± 0.09
1 50 8 83.4 ± 6.5 78.2 ± 4.1 0.63 ± 0.04 0.61 ± 0.05 133.2 ± 6.1 1.07 ± 0.08
1 14 8 82.4 ± 6.4 76.9 ± 5.1 0.66 ± 0.04 0.62 ± 0.04 124.8 ± 4.5 1.09 ± 0.08
1 12 7 75.6 ± 4.7 71.7 ± 5.2 0.66 ± 0.05 0.62 ± 0.04 114.8 ± 4.9 1.08 ± 0.09
Post 50 8 78.7 ± 7.4 75.4 ± 6.1 0.62 ± 0.04 0.60 ± 0.06 128.5 ± 4.9 1.07 ± 0.04

Values are means ± SE.