Skip to main content
. 2014 Aug 20;8(8):ZC32–ZC35. doi: 10.7860/JCDR/2014/8533.4742

[Table/Fig-5]:

Kappa values for intra and inter examiner reproducibility for caries diagnosis using (unaided, Loupes and microscope techniques) different detection techniques

Diagnostic Aids Intra- Examiner Reproducibility Inter- Examiner Reproducibility
Examiner A Examiner B Examiner A - B
Unaided 0.72 0.54 0.46
Loupes 0.53 0.40 0.46
Microscope 0.67 0.74 0.63