Skip to main content
. 2014 Sep;103(3):174–182. doi: 10.5935/abc.20140110

Table 8.

Differences between the stents regarding outcomes

  Cypher® Endeavor® Taxus® p value
n 255 118 291
Mortality 11 (4.3) 2 (1.7) 10 (3.4) 0.47
TVR 19 (9.5) 9 (10.2) 39 (16.8) 0.05
TLR 14 (7.0) 7 (8.0) 22 (9.5) 0.63
Infarction 24 (12.0) 12 (13.6) 41 (17.7) 0.24
Stent thrombosis 3 (1.5) 1 (1.1) 7 (3.0) 0.42
MACE 21 (8.20) 9 (7.6) 27 (9.2) 0.88

TVR: target vessel revascularization; TLR: target lesion revascularization; MACE: major adverse cardiac event.