Table 2 .
Comparison of a Routine vs. Non-routine Endotracheal Tube Insertion
| Raw task data during routine intubation (D&C) | |||
|---|---|---|---|
| Clock Time | Time from 0 | Length (sec) | Task performed |
| . . . 7:29:29 | 116 | 5 | Position patient |
| 7:29:34 | 121 | 8 | Laryngoscopy |
| 7:29:42 | 129 | 10 | Intubation |
| 7:29:52 | 139 | 1 | Secure/manip. airway |
| 7:29:53 | 140 | 3 | *Attending conversation |
| 7:29:56 | 143 | 8 | Secure/manip. airway |
| 7:30:04… | 151 | 7 | Bag ventilation |
| Raw task data from case with NRE during intubation (D&C)—failed intubation | |||
|---|---|---|---|
| Clock Time | Time from 0 | Length (sec) | Task performed |
| *Performed concurrently with preceding task—the total Secure Airway task time was 12 sec. | |||
| . . . 9:44:00 | 174 | 2 | Observe airway |
| 9:44:02 | 176 | 9 | Laryngoscopy |
| 9:44:11 | 185 | 16 | Intubation (esophageal) |
| 9:44:27 | 201 | 7 | Manip. airway (extubation) |
| 9:44:34 | 208 | 28 | Bag ventilation |
| 9:45:02 | 236 | 9 | Laryngoscopy |
| 9:45:11 | 245 | 16 | Intubation |
| 9:45:27 | 261 | 14 | Secure/manip. Airway |
| 9:45:41. . . | 275 | 4 | Bag ventilation |