Skip to main content
. Author manuscript; available in PMC: 2015 Nov 1.
Published in final edited form as: Magn Reson Med. 2014 Aug 28;72(5):1366–1374. doi: 10.1002/mrm.25441

Table 1.

In vivo and ex vivo ADC measurements (n=5) of the adult mouse cortex and hippocampus. Data are presented as group mean ± inter-subject standard deviation.

ADC(μm2/ms) Cortex Hippocampus
In vivo Ex vivo In vivo Ex vivo
PGSE 0.62±0.02** 0.50±0.01 0.64±0.01** 0.53±0.02
50Hz 0.64±0.02** 0.57±0.02 0.65±0.01** 0.56±0.03
100Hz 0.65±0.02 0.62±0.01 0.67±0.01** 0.60±0.02
150Hz 0.66±0.02 0.65±0.01 0.69±0.01* 0.63±0.02
200Hz 0.69±0.02 0.68±0.02 0.72±0.02* 0.66±0.03
ΔfADC(μm2) 0.33±0.05** 0.87±0.08 0.38±0.05** 0.66±0.06

Note: * and ** denote that a two-tailed paired t-test between the in vivo and ex vivo measurements produced a p-value less than 0.01 and 0.001, respectively.