Table 2. Predicted spirometry values for the Brazilian population(16) and those generated by the Global Lung Function Initiative (GLI) equation(19,21) for combinations of age and height in males.
Variable | Age, years | Height, cm | Pereira et al.(16) | GLI(19,21) |
---|---|---|---|---|
FVC, L | 25 | 175 | 5.35 | 5.18 |
50 | 170 | 4.58 | 4.48 | |
75 | 165 | 3.80 | 3.44 | |
LL | 25 | 175 | 4.45 | 4.19 |
50 | 170 | 3.68 | 3.50 | |
75 | 165 | 2.90 | 2.52 | |
FEV1, L | 25 | 175 | 4.50 | 4.35 |
50 | 170 | 3.69 | 3.56 | |
75 | 165 | 2.90 | 2.61 | |
LL | 25 | 175 | 3.74 | 3.51 |
50 | 170 | 2.93 | 2.78 | |
75 | 165 | 2.14 | 1.85 | |
FEV1/FVC | 25 | 175 | 0.85 | 0.85 |
50 | 170 | 0.81 | 0.80 | |
75 | 165 | 0.77 | 0.76 | |
LL | 25 | 175 | 0.77 | 0.73 |
50 | 170 | 0.73 | 0.69 | |
75 | 165 | 0.69 | 0.62 |
: lower limit.