Skip to main content
. 2013 Nov 18;7(6):488–495. doi: 10.4161/pri.27180

Table 2. Bioassay of wires contaminated with the 263K scrapie strain.

Group No Treatment Survival interval ± standard error (days) Clinically affected/ Total
1 Negative controls, stainless steel >505.0 0/3
2 Positive controls, stainless steel 135.0 ± 8.0 3/3
3 360 min photo-Fenton, stainless steel 302.0 ± 29.3 3/8
4 480 min photo-Fenton, stainless steel >505.0 0/8
5 Negative controls, titanium >505.0 0/4
6 Positive controls, titanium 113.8 ± 3.5 4/4
7 360 min photo-Fenton, titanium 202.9 ± 5.8 8/8

After photo-Fenton treatment (224 μg mL−1 Fe3+, 500 μg mL−1 h−1 H2O2, UV-A) wires were intracranially implanted in male golden Syrian hamsters. The survival interval of group 3 was calculated taking into account only the scrapie affected animals.