Skip to main content
. Author manuscript; available in PMC: 2015 Oct 1.
Published in final edited form as: Neuroinformatics. 2014 Oct;12(4):513–534. doi: 10.1007/s12021-014-9226-5

Table 4.

Sensitivity and specificity of four traditional methods and our method.

Methods TL-0mm TL-5mm TN-0mm TN-5mm Our
method
Sensitivity 0.639 0.694 0.583 0.639 0.889
Specificity 0.960 0.966 0.953 0.960 0.988