Resistance, Relative humidity (RH) |
|
Resistance should decrease with RH |
|
Resistance, Frequency |
|
For best response resistance should decreases with frequency |
|
Resistance, Temperature |
|
For best response resistance should decreases with temperature |
|
Capacitance, Relative humidity (RH) |
|
For best response capacitance should increases with RH |
|
Capacitance, Frequency |
|
For best response capacitance should decreases with frequency |
|
Hysteresis |
|
For best response hysteresis loop should be as narrow as possible. |
|
Response and recovery time |
|
For best response recovery and response time should be as minimum as possible, so that the sensor will give fast response |
|
Repetability |
|
For best response the same response should repeat with time |
Stability |
|
For best stability resistance fluctuation should be minimum with time |