Table 1.
General | ||
| ||
Technology | 0.18 μm CMOS 5 M + THKMET | |
VDD | +5 V | |
IDDa | 85 μA | |
Area b | 0.2 mm2 (readout in both sensors) | |
| ||
Sensor Output | ||
| ||
Temperature | Humidity | |
Sensitivity c | 486/°C | 124/% RH |
Sensitivity error d | < ±4.3% | < ±14.5% |
| ||
Temperature Sensor | ||
| ||
Area | 0.023 mm2 (part of readout circuit) | |
Sensitivity | 7753 ppm/°C@37°C | |
Linearity | Compromise between linearity and sensitivity (see text); ideal for TCIREF = 0. | |
| ||
Capacitive Humidity Sensor | ||
| ||
Version 1 | Version 2 | |
Area | 1 mm2 | 0.09 mm2 |
Sensitivity e | 514 ppm/% RH | 584 ppm/% RH |
Static quiescent current;
readout only;
as change in the counter output per measurement unit;
maximum variation for the batch (N = 14) of Version 1;
obtained by measurement of capacitive changes in Version 1 and by frequency ratio in Version 2.