Skip to main content
. Author manuscript; available in PMC: 2014 Oct 28.
Published in final edited form as: Lab Chip. 2012 Mar 1;12(12):2199–2210. doi: 10.1039/c2lc21100a

Table 1.

Quantitative measurements of particle focusing behavior as a function of flow rate Q and RBC volume fraction fRBC. For a given Q and fRBC, the particle Reynolds number Rp, the mean in-focus lateral distance zm from the channel centerline, the bandwidth efficiency βz, and the focusing utility Φy were calculated for polystyrene beads, white blood cells, and PC-3 prostate cancer cells

Q (µl min−1) fRBC Rp zm(µm) σz(µm) βz Φy
Polystyrene Beads 50 0 0.32 12.7 0.7 1.27 0.91
0.07 0.28 13.5 0.9 1.35 0.73
0.33 0.18 12.5 4.5 2.86 0.81
150 0 0.97 12.9 0.5 1.08 1
0.07 0.84 14.1 1.4 1.56 0.96
0.33 0.56 13.9 2.1 1.82 0.87
450 0 2.91 13.6 1.1 1.45 0.86
0.07 2.53 14.2 1.4 1.54 0.91
0.33 1.68 14.4 2.0 1.79 0.86
White Blood Cells 50 0 0.27 14.4 0.9 1.43 0.79
0.07 0.23 15.6 2.0 1.56 0.55
0.33 0.16 11.2 5.3 3.13 0.40
150 0 0.80 15.5 0.6 1.28 0.72
0.07 0.70 16.5 1.9 1.82 0.61
0.33 0.46 15.3 3.3 2.44 0.54
450 0 2.41 16.1 1.0 1.43 0.75
0.07 2.10 16.5 1.9 1.82 0.61
0.33 1.39 16.2 2.9 2.33 0.57
PC-3 Cells 50 0 1.01 8.6 2.1 1.47 1
0.07 0.88 8.6 2.5 1.56 1
0.33 0.58 9.9 2.0 1.45 0.92
1 0.25 1.0 0.9 1.22 0.17
150 0 3.04 10.1 1.1 1.25 1
0.07 2.64 10.3 1.4 1.32 1
0.33 1.76 10.2 1.8 1.41 1
1 0.76 1.1 1.0 1.22 0
450 0 9.11 9.9 1.2 1.28 1
0.07 7.92 11.0 1.3 1.28 1
0.33 5.27 10.8 1.5 1.35 1
1 2.28 1.7 1.4 1.32 0