Skip to main content
. 2014 Nov;27(11):1615–1622. doi: 10.5713/ajas.2014.14305

Table 3.

Moisture concentrations (%) in whey permeate, whey powder, and lactose determined by various oven methods and the Karl Fischer (KF) method (Exp. 2)1

Ingredient Oven-drying method KF method3

Drying time (h) Drying temperature (°C)

1352 95 105 115 125
Whey permeate5,6 1 7.5±0.1 1.3±0.01 1.6±0.02 3.3±0.15 5.5±0.13 3.0±0.09
2 1.4±0.03 2.3±0.03 3.4±0.05 6.1±0.05
3 1.5±0.13 2.74±0.03 3.8±0.03 6.3±0.03
4 1.5±0.00 2.6±0.05 4.8±0.13 7.0±0.02
5 1.5±0.01 3.7±0.11 5.2±0.05 6.7±0.04
6 1.5±0.01 2.8*±0.03 5.8±0.03 7.4±0.05
9 1.6±0.01 3.5±0.02 6.3±0.01 8.0±0.03
15 1.6±0.01 4.4±0.01 6.4±0.01 9.7±0.13
24 1.7±0.00 4.8±0.03 6.8±0.01 12.9±0.17
Whey powder5,6 1 7.7±0.06 1.7±0.01 2.0±0.00 2.9±0.06 5.8±0.14 3.8±0.08
2 1.8±0.01 2.3±0.02 2.8±0.04 6.2±0.04
3 1.8±0.01 2.64±0.02 3.1±0.03 5.9±0.04
4 1.9±0.03 2.6±0.02 4.2±0.08 7.2±0.02
5 2.0±0.03 3.2±0.07 4.5±0.04 7.0±0.04
6 1.9±0.00 2.7±0.02 5.5±0.04 7.4±0.07
9 2.1±0.01 3.1±0.02 5.9±0.01 7.8±0.02
15 2.2±0.03 3.5*±0.03 6.8±0.03 8.4±0.02
24 2.2±0.01 4.3±0.04 7.0±0.01 9.2±0.01
Lactose5,6 1 5.1±0.01 0.3±0.16 0.3±0.03 1.8±0.08 3.8±0.11 4.5±0.05
2 0.2±0.00 0.9±0.01 2.0±0.04 4.4*±0.05
3 0.1±0.01 1.24±0.02 2.5±0.02 4.9±0.02
4 0.2±0.00 1.3±0.00 3.5±0.06 5.1±0.00
5 0.2±0.00 1.8±0.06 4.0±0.01 5.1±0.00
6 0.1±0.01 1.5±0.03 4.5±0.03 5.1±0.01
9 0.2±0.01 2.0±0.01 5.0±0.01 5.1±0.00
15 0.2±0.00 2.6±0.01 5.0±0.01 5.1±0.01
24 0.2±0.00 3.2±0.03 5.1±0.01 5.1±0.01
1

n = 2 for KF and n = 3 for all oven methods.

2

An oven method drying at 135°C for 2 h (AOAC, 2005; method 930.15).

3

The Karl Fischer method (AOAC, 2005; method 2001.12).

4

An oven method drying at 105°C for 3 h (Shreve et al., 2006; NFTA 2.2.2.5).

5

The weight loss-on-drying measured by an oven method drying at 135°C for 2 h (AOAC, 2005; method 930.15) differed from the moisture measured by the KF method (p<0.05).

6

The weight loss-on-drying measured by an oven method drying at 105°C for 3 h (Shreve et al., 2006; NFTA 2.2.2.5) differed from the moisture measured by the KF method (p<0.05).

*

This method had the least deviation (%) from the KF method.