Skip to main content
. 2014 Sep;11(7):1064–1074. doi: 10.1513/AnnalsATS.201404-161OC

Table 4.

Diagnostic characteristics of obstructive sleep apnea prediction tools with 95% confidence intervals in validation group 1

  OSUNet MNC STOP-BANG
Sensitivity 0.63 (0.51–0.74)* 0.89 (0.80–0.95) 0.97 (0.91–1.00)
Specificity 0.70 (0.58–0.80)* 0.30 (0.20–0.42) 0.12 (0.06–0.21)
PPV 0.67 (0.54–0.78)* 0.55 (0.46–0.64) 0.51 (0.43–0.60)
NPV 0.66 (0.55–0.76) 0.74 (0.55–0.88) 0.82 (0.48–0.98)
Positive LR 2.08 (1.42–3.06)* 1.28 (1.08–1.51) 1.10 (1.01–1.20)
Negative LR 0.53 (0.38–0.74) 0.36 (0.17–0.76) 0.23 (0.05–1.04)

Definition of abbreviations: LR, likelihood ratio; MNC, modified neck circumference; NPV, negative predictive value; PPV, positive predictive value; STOP-BANG, Snoring, Tiredness, being Observed to stop breathing during sleep, high blood Pressure, Body mass index greater than 35 kg/m2, Age greater than 50 years, Neck circumference greater than 40 cm, and male Gender.

Note: n = 149.

*

Significantly different compared with MNC and STOP-BANG.

Significantly different compared with STOP-BANG.