Table 5. Accuracy of the BADRI risk model as applied to the European dataset using various cut-off values (risk scores).

RiskScore Patientswith ADR Patientswithout ADR Sensitivity Specificity Youden’sindex (J) 1-specificity
>0 53 342 0.95 0.20 0.15 0.80
>1 45 232 0.80 0.46 0.26 0.54
>2 26 108 0.46 0.75 0.21 0.25
>3 10 22 0.18 0.95 0.13 0.05
>4 1 3 0.02 0.99 0.01 0.01

Note Youden’s Index is largest when the cut-off value is >1 (with sensitivity of 80% and specificity of 46%).