Skip to main content
. Author manuscript; available in PMC: 2014 Oct 30.
Published in final edited form as: Aerosol Air Qual Res. 2011 Jun 1;11(3):315–322. doi: 10.4209/aaqr.2010.08.0072

Table 2.

Summary of DustTrak wood smoke correction factors.

Sampling Scenario Wood Smoke Source Correction Factor ± Std Dev Description
Controlled Laboratory Woodstove Burns Wood stove 2.18 ± 1.22 DustTraks vs MetOne BAM (FEM)
Indoor Forest Fire Smoke Wildland forest fire 1.59 ± 0.28 DustTrak vs Leland/PEM
Indoor Forest Fire Smoke Wildland forest fire 1.70 ± 0.22 DustTrak vs BGI PQ200 (FRM)
Indoor/Residential Air Wood stove homes 1.60 ± 1.05 DustTrak vs Leland/PEM
Ambient Air Wood stove community 1.43 ± 0.61 DustTrak vs MetOne BAM (FEM)