Skip to main content
. 2014 Oct 21;2014:701839. doi: 10.1155/2014/701839

Table 1.

Results of spirometry and body plethysmography, demonstrating forced expiratory volume in the 1st second in percent of expected value (FEV1%), forced ventilatory capacity in percent of expected value (FVC%), the ratio between FEV1 and FVC, and diffusing capacity of the lung for carbon monoxide in percent of expected value (DLCO%) and 6-minute walking tests in 7 patients with Hb Aalborg.

Patient 1 (woman) Patient 2 (man) Patient 3 (woman) Patient 4 (woman) Patient 5 (woman) Patient 6 (man) Index person
FEV1 (%) 106 128 94 87 117 106 117
FVC (%) 108 122 103 107 104 98 134
FEV1/FVC 87 78 65 94 99 91 74
DLCO (%) 59 69 67 69 76 80 66
Walking distance (m) 417 480 562 420 568 551 273