Skip to main content
. 2014 Jul 25;16(1):53. doi: 10.1186/s12968-014-0053-5

Table 2.

Relevant imaging parameters for the sequences used

  TOF T1-w TSE T2-w TSE MATCH
TE/TR (ms)
3.6/21
12.0/800
59.0/4000
4.2/10.8
Field-of View (mm2)
150 × 200
140/160 × 140/160
140/160 × 140/160
140/160 × 140/160
In-plane resolution (mm2)
0.87 × 0.52
0.55/0.63 × 0.55/0.63
0.55/0.63 × 0.55/0.63
0.55/0.63 × 0.55/0.63
Number of slices
84 slices (with 3 slabs)
16
16
16 (plus 4-slice oversampling)
Slice thickness (mm)
1.0 (with 19% overlap)
2
2
2
Number of Average
1
2
2
1
Flip angle (o)
25
136-170
120-160
8
Echo train length
-
7
12
55-67*
Bandwidth (MHz)
250
407
407
130
Parallel factor (GRAPPA)
2
-
-
2
Scan time (min:sec) 2:27 2:56 3:24 4:45