Skip to main content
. 2014 Sep 15;2(3):185–191.

Table 1.

Measurements of First Electrodiagnostic Test Versus Last Electrodiagnostic Test

Parameter N Mean First Test Median First Test SD First Test Mean Last Test Median Last Test SD Last Test Correlation P Value

Median DML (ms) 62 4.7 4.2 1.6 4.9 4.4 1.8 0.16 0.075
Median DSL (ms) 55 4.0 3.8 0.67 4.0 3.9 0.60 NS 0.72
Median/ulnar mixed sensory nerve studies (ms) 41 1.0 0.78 0.63 0.94 0.73 0.71 NS 0.45
Median motor amplitude (mV) 62 9.0 9.0 3.0 8.9 9.1 2.8 NS 0.60
Difference between median and ulnar DML on same side (ms) 57 2.2 1.8 1.7 2.4 1.9 1.8 0.19 0.038

N=Number; SD=Standard Deviation; DML=Distal Motor Latency; DSL=Distal Sensory Latency; NS=Not Significant; ms=milisecond; mV=milivolt.

The number in bold indicates a significant P value (P<0.05).