Skip to main content
. Author manuscript; available in PMC: 2014 Nov 12.
Published in final edited form as: IEEE Trans Audio Speech Lang Process. 2013 Sep;21(9):1929–1939. doi: 10.1109/TASL.2013.2263138

TABLE II.

Estimation error of ACC-based measures of GVV with OVV-based measures as reference. pp = percentage points.

Measures Units Absolute error
Mean ± Stdv
Relative error
Mean ± Stdv
H1–H2 dB 3.2 ± 2.2 31.1% ± 27.3 pp
HRF dB 2.4 ± 2.0 28.4% ± 29.1 pp
AC Flow mL/s 15.8 ± 14.4 6.8% ± 5.8 pp
MFDR L/s2 26.8 ± 20.6 9.3% ± 7.5 pp
RMSE GVV mL/s 25.0 ± 14.1 10.4% ± 4.0 pp
RMSE dGVV L/s2 74.2 ± 49.1 25.7% ± 10.3 pp