Skip to main content
. 2014 Feb 3;26(2):56–62. doi: 10.1016/j.sdentj.2013.12.007

Table 3.

Mean and standard deviations of roughness values for acrylic specimens polished with different systems (μm). The value with the same superscript letter indicates no significance.

Comparison Light-cured acrylic resin (mean ± SD) Heat-cured acrylic resin (mean ± SD)
Resilit High-luster Polishing Liquid 0.05a ± 0.01 0.07a ± 0.01
Universal Polishing Paste 0.06a ± 0.01 0.08a ± 0.02
Abraso-Star K50 0.06a ± 0.00 0.10a ± 0.05
Pumice 0.11a ± 0.04 0.10a ± 0.01
Jet Seal Liquid 0.29b ± 0.04 0.29b ± 0.05
AcryPoint 0.23b ± 0.06 0.25b ± 0.05