Change in the I0/I and τ0/τ ratios for the emissive species in air and O2-saturated samples.

Solvent Emissive species Air Oxygen
I0/I τ0/τ I0/I τ0/τ
Hexane M* E* CS* 5.4 6.3 1.2 5.5 3.1 1.0 11.4 41.5 1.5 8.4 11.1 1.1
Dichloromethane M* E* CS* 2.2 2.5 1.2 3.0 1.9 1.2 4.6 11.2 1.9 [a] 5.5 1.3
Ethyl acetate M* E* CS* 3.5 5.2 1.1 3.6 2.6 1.1 8.7 33.5 1.2 7.8 8.6 1.1
Tetrahydrofuran M* E* CS* 3.1 4.7 1.0 4.0 2.7 0.93 7.6 30.0 1.0 8.0 7.2 0.97
Chloroform M* E* CS* 2.2 3.7 1.2 1.7 1.7 1.0 4.1 16.9 1.5 3.8 4.2 1.3
Toluene M* E* CS* 2.0 2.4 1.3 2.9 2.4 1.0 7.9 32.7 1.9 8.7 7.4 1.3
Dioxane M* E* CS* 2.2 2.4 1.1 1.8 1.7 1.2 4.6 11.8 1.5 4.3 4.1 1.4

[a] The lifetime value was close to that of the detection limit of the instrument (<1 ns).