Skip to main content
. 2014 Apr 1;14:41. doi: 10.1186/1471-2261-14-41

Table 3.

Detection of relevant arrhythmias – 24-hour Holter ECG versus intermittent ECG

  Intermittent ECG positive Intermittent ECG negative Added results
24-hour Holter ECG positive
2
1
3*
24-hour Holter ECG negative
11
81
92
Added results 13 82 Total: 95

*24-hour Holter ECG added results. n = 3, 3.2%, [95% CI 1.1–8.9].

Intermittent ECG added results. n = 13, 13.7%, [95% CI 8.2–22.0].