Skip to main content
. 2014 Oct 27;111(45):16077–16081. doi: 10.1073/pnas.1410865111

Table 2.

Prescribed absorbed doses from radiation components for 5-Gy absorbed dose to precancerous tissue and corresponding beam-only irradiation

Tissue Boron concentration, ppm γ-Photons, Gy Induced protons (14N), Gy Boron, Gy Absorbed dose, Gy
Total background Total
MAC-TAC BNCT
 Tumor 66.6 ± 16.1 0.9 ± 0.1 0.8 ± 0.2 19 ± 6 1.7 ± 0.2 21 ± 6
 Precancerous tissue 11.3 ± 6.2 0.9 ± 0.1 0.8 ± 0.2 3 ± 2 1.7 ± 0.2 5 ± 2
 Normal tissue 7 ± 5.5 0.9 ± 0.1 0.8 ± 0.2 2 ± 2 1.7 ± 0.2 4 ± 2
Beam only
 Tumor, precancerous tissue, and normal tissue 0.9 ± 0.1 0.8 ± 0.2 1.7 ± 0.2 1.7 ± 0.2

The mean thermal neutron fluence at the irradiation position was 3.9 × 1012 ± 8 × 1011 n cm−2 and the irradiation time ranged from 8 to 9 min. Values are presented as means ± SD.