Abstract
Background
Mapping of the great saphenous vein is very important for planning of peripheral and coronary bypass surgery. This study investigated mapping of the great saphenous vein as an adjunct to peripheral MR angiography using a blood pool contrast agent in patients who were referred for evaluation of peripheral arterial occlusive disease and bypass surgery.
Methods
38 patients with peripheral arterial occlusive disease (21 men; mean age: 71 years, range, 44–88 years) underwent peripheral MR angiography using the blood pool contrast agent Gadofosveset trisodium. Apart from primary arterial assessment images were evaluated in order to determine great saphenous vein diameters at three levels: below the saphenofemoral junction, mid thigh and 10 cm above the knee joint (usability: diameter range: >3 and <10 mm at one level and >3.5 and <10 mm at a neighboring level). Duplex ultrasound was performed by an independent examiner providing diameter measurements at the same levels. Additionally, vessel usability was determined intraoperatively by the vascular surgeon during subsequent bypass surgery.
Results
Mean venous diameters for MR angiography/duplex ultrasound were 5.4±2.6/5.5±2.8 mm (level 1), 4.7±2.7/4.6±2.9 mm (level 2) and 4.4±2.2/4.5±2.3 mm (level 3), respectively, without significant differences between the modalities (P = 0.207/0.806/0.518). Subsequent surgery was performed in 27/38 patients. A suitable saphenous vein was diagnosed in 25 and non-usability was diagnosed in 2 of the 27 patients based on MR angiography/duplex ultrasound, respectively. Usability was confirmed by intraoperative assessment in all of the 24 patients that received a venous bypass graft in subsequent bypass surgery. In 1 case, in which the great saphenous vein was assessed as useable by both MR angiography and duplex ultrasound, it was not used during subsequent bypass surgery due to the patients clinical condition and comorbidities.
Conclusion
Simultaneous mapping of the great saphenous vein as an imaging adjunct to peripheral MR angiography with a blood pool contrast agent is an alternative to additive duplex ultrasound in patients undergoing subsequent peripheral bypass grafting.
Introduction
The first bypass surgery with an autologous saphenous vein was carried out by Jean Kunlin in 1948 [1]. Nowadays bypass grafting has been fully established as a standard surgical treatment option in peripheral arterial occlusive disease (PAOD). An autologous saphenous vein is generally regarded as the material of choice for a femorodistal bypass [2]–[4], since it provides the best patency rates [4] and its anatomic position, its length and its wall strength make it suitable to be used as an arterial bypass graft [5]. This is particularly true if it is of good quality i.e. wide enough in diameter as well as free of varicosities, thrombotic segments and too many tributaries [6].
Since the 1970 s, the preoperative assessment of the saphenous vein regarding its anatomic configuration, venous abnormalities and pathologic changes has been proven successful in evaluating its suitability as a bypass graft in arterial reconstructions [7], [8]. In the 1980 s, the use of phlebography [9] was challenged by B-mode ultrasound [10], [11] being a procedure which is not invasive, prevents confusion concerning the discrimination of deep and superficial veins and last but not least renders more accurate information about the venous diameters [12], [13].
The advantages of the preoperative saphenous vein mapping, i.e. reduction in morbidity, operation time and hospital stay [13], have been evaluated in several studies on coronary artery grafts [14], [15] as well as peripheral bypass surgery [16], [17].
The major quantitative parameter which has to be determined during venous mapping and has been identified as the predominant technical factor in predicting primary patency, primary assisted patency and secondary patency is the internal venous diameter [4]. In this context the superiority of veins having a larger diameter (>3.5 mm) over narrow ones (<3 mm) is well established [4], [18]. However, Wengerter et al. demonstrated that grafts having a diameter of 3.5 mm as well as grafts which have a diameter of 3.0 mm and are at the same time not longer than 45 mm, present similar patency rates compared to grafts which have a diameter of at least 4.0 mm [19]. This highlights the point that the decisive factor for the short- and long-term success of the bypass surgery is the suitability of the venous conduit, which may be even more important than the quality of the arteries.
B-mode ultrasound has been established as the gold standard in the preoperative mapping of the great saphenous vein (GSV) [20]. However, this noninvasive procedure is highly operator dependent, very time consuming, especially in patients who have already undergone venous surgery, and has technical limitations in patients with edema, obesity and ulcerations.
Contrast-enhanced magnetic resonance angiography (CE-MRA) is considered an alternative to digital subtraction angiography (DSA) in the diagnosis and assessment of patients with peripheral arterial occlusive disease [21], [22] and increasingly replaces DSA in the imaging of the arterial vascular system [23]. However, spatial resolution is limited with standard extracellular Gadolinium chelates during “first pass” imaging. Recently, a contrast agent, with a reversible albumin binding and an extended intravascular retention and contrast enhancement [24], a “blood pool contrast agent (BPCA)”, was approved by the U.S. Food and Drug Administration (FDA). During “first pass” it offers an image quality which, depending on the dose, is at least as good as that of standard extracellular contrast agents [25]–[27]. In addition to first pass MR angiography, blood pool contrast agents allow contrast enhancement during an “equilibrium phase” (i.e. steady state) due to the lack of a relevant extravasation of the contrast agent into the interstitial space. Providing an imaging window of up to 60 minutes [28], the equilibrium phase facilitates the acquisition of much higher spatial resolution images without a significant loss of vessel-to-background contrast [28]–[30]. Steady state MRA with the blood pool contrast agent Gadofosveset trisodium in patients with peripheral arterial occlusive disease was found to render better results than first pass imaging alone [31] and leads – as an add-on – to the simultaneous visualization of the venous system [30]. The additional visualization of veins to that of arteries is inherent to steady state MRA and requires neither a second contrast administration nor any other change of examination parameters. As early as in 1998, Grist et al. indicated the benefits which might be drawn from the simultaneous visualization of arteries and veins in the steady state imaging with Gadofosveset [29]. Today, preliminary data supports the hypothesis that this approach allows for MR-venography as an add-on to the MRA of the arterial system [32]–[34]. Gadofosveset-enhanced MR-imaging has already been proven successful in the detection of thromboembolic processes. Deep venous thrombosis [35] as well as collateral pathways in patients suffering from a massive thromboembolic occlusion of the central veins were reliably detected; the latter could even be achieved in a way better than conventional X-ray-based phlebography [30].
The basis of this work was the hypothesis that peripheral MRA in the steady state using a blood pool contrast agent to image the size and quality of great saphenous veins would be a useful adjunct to arterial phase MRA to improve the performance of peripheral bypass surgery in patients with PAOD. Thus, the purpose of this study was to prospectively determine the accuracy of high-spatial-resolution steady-state MR angiography using the blood pool contrast agent Gadofosveset trisodium in comparison to color-coded duplex ultrasound (DUS) as the standard of reference in order to assess the usability of autologous saphenous veins for subsequent peripheral bypass surgery. Results were correlated with intraoperative findings.
Methods
Ethics Statement
The study protocol was approved by the institutional ethic committee of the University Hospital Bonn, Germany (approval number: 132/07). All patients provided written informed consent.
Patients
This prospective, intraindividual comparative study included 38 consecutive patients (mean age, 71 years; range, 44–88 years) (21 men, 17 women) (table 1) with peripheral arterial occlusive disease who underwent 3D-enhanced MR angiography in preparation for or evaluation of a peripheral (femoropopliteal, popliteocrural or femorocrural) bypass surgery (figure 1).
Table 1. Clinical and demographic characteristics of the study population.
PAOD stage II b | PAOD stage III | PAOD stage IV | |
number of patients | 13 | 9 | 16 |
age range - years | 57–78 | 45–88 | 56–85 |
male sex - no. | 7 | 3 | 11 |
All patients were of white ethnicity.
Clinical inclusion criteria were PAOD stage IIb-IV (Fontaine classification) and indication for MRA. Exclusion criteria were contraindications for 3D contrast-enhanced MR angiography (e.g. allergy, metallic implants that are incompatible with MR imaging including pacemakers). The indication for MRA was defined clinically by the vascular surgeons. Every patient who was enrolled into the study also underwent DUS. 3D contrast-enhanced MR angiographic and ultrasound examinations were carried out in random order. MR-angiographic venous mapping was performed as an adjunct to the BPCA-MRA which was done in order to assess arterial occlusive disease. A possible surgical intervention was not delayed for any patient because of his or her participation in this study.
MR Angiography
MR imaging was performed as previously described [31]: A 1.5-T whole–body imager (Achieva; Philips Healthcare) (maximum gradient amplitude, 33 mT/m; slew rate, 200 T/m/sec) was used to acquire three-dimensional contrast-enhanced MR angiographic sequences of the vasculature. While images of the lower legs were obtained using a commercially available flexible four-channel phased-array coil (Philips Healthcare, Best, the Netherlands), an integrated body coil served for image acquisition of the upper legs and pelvic region. Using a biphasic injection protocol, Gadofosveset trisodium was administered with an automatic power injector (Spectris; Medrad Europe, Beek, the Netherlands) at a flow rate of 1.2 ml/sec followed by a 25 ml saline flush at a flow rate of 0.6 ml/sec. As soon as the contrast medium was detected at the level of the common iliac arteries by means of fluoroscopic triggering, the acquisition of first pass images was started. The imaging protocol as well as technical parameters of the T1-weighted gradient-echo sequences that were used for first-pass and steady-state MR angiography are shown in figure 2 [31], [35]. Steady-state imaging followed first-pass imaging 4 minutes after contrast injection [36].
Contrast Agent
Gadofosveset trisodium (Vasovist, Bayer Healthcare, Leverkusen, Germany; discontinued, now available in the US and Canada as Ablavar, Lantheus Medical Imaging, N. Billerica, MA) was the first intravascular contrast agent approved for use with MRA in the European Union, Switzerland, Turkey, Canada and Australia [37]. In 2008 it became the first contrast agent specifically approved for MR angiography in the US and Canada by the FDA in order to investigate aortoiliac occlusive disease. Due to an additional diphenylcyclohexyl group, this gadolinium-based contrast agent strongly but reversibly binds to human serum albumin resulting in a higher relaxivity (r1 = 19 L *mmol−1 sec−1 at 1.5 T and 37°C in plasma) and an extended plasma half-life as compared to standard Gadolinium-containing contrast agents. A dose of 0.03 mmol/kg has been proven safe and effective for imaging of peripheral vascular disease [38] and was applied in all patients in our study.
Image analysis of MR Angiography
The maximum venous vessel diameter of the GSV (area of enhancing vessel lumen) was measured on cross-sectional images perpendicular to the flow axis by one radiologist (10 years of experience in vascular radiology) on multiplanar reformats of steady-state MR angiograms on a post-processing workstation (Viewforum; Philips Healthcare, Best, Netherlands) (figure 3–5). Each vein was measured at three levels: at the level just below the groin, at the level of the mid-thigh and 10 cm above the knee joint. To account for both the influence of the graft diameter on the patency rate and the influence of the graft length on the minimal diameter regarded as useable, [4] we decided to rate veins suitable which offered a diameter of at least 3.5 mm at one level and simultaneously a diameter of at least 3.0 mm at a neighboring level. In accordance to clinical practice we defined an upper limit of 10 mm. Nodular varicosities as well as other venous pathologies like thrombosis were exclusion criteria for use in bypass surgery. In order to minimize intraindividual measuring variability, three independent measurements were noted in each of the defined points and the mean was taken for comparison. Moreover a fixed magnification factor of 4 was applied. The reader was blinded regarding the patientś names, clinical histories and the results of other diagnostic procedures, including color-coded duplex sonography.
Color-coded duplex sonography
Examinations were performed with the patient in supine position. A HD 11 ultrasound system (Philips Healthcare, Best, the Netherlands) with a 5–10 MHz ultrasonographic transducer was used to visualize the saphenous vein in transverse scans. Starting from the groin, the main trunk was tracked distally to the knee joint. Analogously to the MR angiographic image analysis, three independent measurements were taken from the cross-sectional scan at each level (figure 3–5) and the mean value was calculated. The reader of the DUS was blinded with regard to the results of the MRA.
Intraoperative Evaluation
The preparation of the GSV was carried out through an inguinal incision and a few auxiliary incisions along the saphenous vein. The vein was dissected and measured with a ruler as seen in figure 6. Branches were ligated, the vein was cut to size if necessary and anastomosed at its proximal and distal ends. Absolute values were not compared statistically because measurements were performed on dissected veins that are not in the same physiological condition as in vivo.
Statistical analysis
Students t-test for paired samples was used to test the differences between the diameters measured by DUS and MR angiography based on a venous segment level. A P value of less than 0.050 was considered to indicate statistical significance. Correlation between the MR-tomographic and sonographic data was analyzed using Pearsońs correlation coefficient. All statistical analyses were performed with the Statistical package for Social Sciences (SPSS) version 17.0 (SPSS, Chicago, Il, USA).
Results
3D steady-state MR angiography was successfully completed in 38 patients (76 assessable legs). Legs, which offered no measureable saphenous vein due to stripping of the saphenous vein (14/76), amputation at the level of mid-thigh (1/76) and absent definability in MRA as well as in sonography (no available level for comparison) (3/76) were excluded. Finally a total of 58 veins were available for intraindividual comparison at level 1, 54 veins for comparison at level 2, and 49 veins for comparison at level 3. The difference between the number of measurements available at the different levels is due to the fact that in some cases a segment (i.a. a level) of the vein was not included in the scanned volume (5/13) or certain levels were not clearly definable in MRA and/or DUS (8/13). All segments containing the measuring points were satisfactorily displayed on steady-state MR angiography as well as with DUS. Altogether, 161 comparative measurements were performed (Table S1).
Mean venous diameters in MRA/DUS for level 1, 2 and 3 were 5.4±2.6 mm/5.5±2.8 mm, 4.7±2.7 mm/4.6±2.9 mm and 4.4±2.2 mm/4.5±2.3 mm respectively, without significant differences between the two modalities (P = 0.207/0.806/0.518, df = 57/53/48) (figure 7). The venous diameters measured were higher on steady-state MR angiography than on color-coded duplex sonography in 54 out of 161 measurements (33.54%) (overestimation) and lower on 82 out of 161 measurement (50.93%) (underestimation). In 25 out of 161 measurements (15.53%) the two methods yielded identical values. The mean values of the positive and negative differences (MRA-DUS) are 0,52±0,67 mm and −0,45±0,59 mm, respectively, with an overall mean of differences (MRA-DUS) of −0,06±0,72 mm.
27 of the 38 patients underwent subsequent bypass surgery. In all of these 27 patients, the MR-angiographic assessment and the independent sonographic evaluation showed the same results regarding the suitability of the vein which was considered as bypass conduit. A suitable saphenous vein was diagnosed in all of the 24/27 patients that received a venous bypass conduit. Intraoperative findings confirmed usability in these 24 patients (13 femoropopliteal, 6 popliteocrural and 5 femorocrural bypasses). Non-usability was found in 2/27 patients based on MRA/DUS: In one of these patients the diameter of the respective saphenous vein was too small, the second patient had nodular varicosities. A prosthetic graft was used for reconstruction in both patients. In 1/27 patients a prosthetic graft was utilized despite the usability of the great sapehnous vein based on MRA and DUS findings. This decision was taken by the surgeons due to the patients clinical condition and comorbidities (including coronary heart disease) in order to minimize the duration of the operation as well as to save the saphenous vein for a potential coronary bypass surgery. In 11 patients no bypass surgery was performed.
Discussion
Patients suffering from PAOD often present with concomitant venous disease [39].
In some patients that are evaluated for bypass surgery, veins or parts of them have already been removed due to varicosities or previous arterial surgery. Furthermore, the correct identification of a suitable vein helps to prevent unnecessary large dissections in already ischemic limbs [5], [40] and thereby reduces postoperative leg morbidity [13]. As such, the assessment of the usability of veins as a bypass graft is an indispensable part of the preoperative workup [41].
Our study demonstrates the diagnostic accuracy of MRA with a BPCA in comparison to DUS in the assessment of the luminal diameter of the GSV. Venous mapping was included in the MR-angiographic examination for arterial stenosis grading without the need of a change of examination parameters or any additional diagnostic step in the patient management. We compared sonographic and MR-angiographic measurements and tested the hypothesis that both modalities provide the same results concerning the usability of the GSV as a bypass conduit.
The visualization of the veins in the equilibrium phase of the MRA with Gadofosveset trisodium offered reliable results with regard to the luminal diameter of the GSV in our study population. Statistical analysis showed no significant differences between sonographic and MR-angiographic measurements. Usability (25/27) and non-usability (2/27) were diagnosed consistently by DUS as the standard of reference and MRA. Additionally, usability was verified by the intraoperative assessment of the vein in all patients that received a venous bypass conduit in subsequent bypass surgery.
MRA with the BPCA Gadofosveset trisodium has been proven to be safe, well-tolerated and highly efficient in patients with vascular disease [36], [42]. In 2000, a new disease which is now called nephrogenic systemic fibrosis (NSF) was first described [43]. In 2006, a link between NSF and the exposure to gadolinium-based contrast agents was observed [44], [45]. NSF is very rare and limited to patients with renal impairment [46], [47]. Following studies indicated that NSF almost exclusively occurs after administration of linear, non-ionic gadolinium-based contrast agents [44], [45]. Moreover a prolonged exposure to the contrast agent due to renal insufficiency is suggested as a factor in the pathogenesis of NSF [44], [45]. Although Gadofosveset trisodium is a gadolinium-based contrast agent with a linear structure and an extended plasma half life, so far no unconfounded cases of NSF after administration of a BPCA have been reported [44]. One reason for this might be the high efficiency of Gadofosveset trisodium which results in the use of a much lower Gadolinium concentration as compared to extracellular contrast agents [44]. Nevertheless, a responsible use of gadolinium-based contrast agents in patients with renal impairment is still obligatory.
The sequences needed for first pass and steady state MRA with a BPCA can be easily applied at any MR imaging system and allow for both arterial stenosis grading and the evaluation of venous diameters within the same scan with just a single-dose of contrast agent [35]. Traditionally, venous enhancement was considered a relative drawback of first-pass as well as of steady-state imaging because of impairment of arterial delineation [29], [30]. However, modern steady-state imaging with its increase in spatial resolution and the possibility to acquire isotropic voxels has proved to allow for a distinct analysis of arteries and veins without overlay [30], [31]. Our study lines with previous results that prove the potential of simultaneous visualization of arteries and veins, which was initially postulated in 1998 in view of examining the entire vasculature of the lower extremity in a single imaging procedure [29].
The accuracy of CE-MRA with a BPCA in arterial stenosis grading as compared with digital subtraction angiography (DSA) has already been demonstrated [31], [48]–[50]. Yet, few studies have investigated the inherent potential of the simultaneous visualization of arterial and venous structures in steady state imaging [33]–[35]. A recent study by Hadizadeh et al. showed that BPCA-MRA can reliably detect incidental venous thrombosis in patients undergoing peripheral MRA because of suspected PAOD [35]. Having demonstrated the reliability of BPCA-MRA in the venous diameter measurement and thus the assessment of the GSV as a bypass conduit, our findings support the usability of BPCA-MRA for simultaneously grading arterial stenosis and visualizing the peripheral veins of the lower extremities in a diagnostically conclusive way.
Our study has several limitations. In the first place, the comparison of the mean venous diameters for the three levels as well as the comparison of the single measurements point out, that MRA in comparison to DUS tends to somewhat over- or underestimate the vessel diameter. However, the fact that the diagnosis of usability versus non-usability by MRA and DUS was consistent in all cases indicates that these slight differences of BPCA-MRA and DUS can practically be neglected. Still, it has to be taken into consideration that a larger study population will increase statistical power. Secondly, the fact that the MRA was carried out as a routine examination for the evaluation of the arterial system, in some cases resulted in the MR technologist accidently excluding the saphenous vein from the scan volume, leading to a reduced number of available segments for comparisons of level 2 (54/76) and 3 (49/76) diameters in comparison to level 1 (58/76). In relation to DUS [19], an inherent limitation of the MR-angiographic examination is the inability to preoperatively mark the course of the veins on the skin as a guide for bypass surgery [10]. However, similar to conventional venography (phlebography), MRA offers a ’roadmap’ of the entire vascular system of the lower extremity for treatment planning [21], especially if curved multiplanar reformats are reconstructed (figure 8). In combination with the option to examine the vascular system in different planes, diagnostic analysis and treatment planning are facilitated [21] even in cases of difficult sonographic evaluation due to obesity, previous surgical interventions, multiple collaterals or varicosities. Moreover, in contrast to phlebography, the depth of the saphenous vein as well as the distinction between deep and superficial veins is clearly evident. Yet, the currently limited access to post-processing workstations might hamper the surgeons first-hand preoperative look at the saphenous vein.
In this context, the benefits of DUS are well known: it is a noninvasive, relatively cheap, mobile and adjustable procedure free of ionizing radiation and contraindications and risks related to strong magnetic fields [21]. Keeping this in mind, BPCA-enhanced MRA for assessment of the GSV may appear a rather expensive and inconvenient approach in relation to DUS. However, the MR-angiographic assessment of the GSV vein is not proposed as a separate examination but as an adjunct to MRA which is anyway implemented for evaluation of the run-off arteries. Since the ’add-on’ only relates to image analysis and not to the MRA procedure itself, most of the advantages of DUS mentioned above are outweighed. The duration of performing the bilateral image analysis of the GSV by the radiologist, which in our cohort was between 3 to 8 minutes, is actually the only additional time and cost factor caused by the MR-angiographic evaluation of the GSV. The bilateral sonographic examination took between 5 to 15 minutes without calculating the patient or equipment transport required. Moreover, the MRA technique is less examiner-dependent than DUS, can be documented in a standardized way and can be reanalyzed at any time. Furthermore, the ability to assess arteries and veins at the same time within one single diagnostic test, reduces the number of examinations, simplifies preoperative diagnostics as well as patient management and may thus shorten the length of the hospital stay [35].
Another limitation of this study was due to the surgical practice that a vein identified as unusable by DUS did not undergo an additional intraoperative evaluation. An intraoperative evaluation of such veins would generally not yield an assessment differing from the ultrasonographic evaluation, which renders them unsuitable for bypass surgery. Its intraoperative exploration would therefore cause unnecessary trauma to the patient.
A final limitation of our study is the fact that in the bypass surgeries performed, the use of the GSV was often not limited to its supragenual segment. In several cases the length of the bypass required resulted in the additional intraoperative dissection and use of the infragenual segment of the GSV. Intraoperatively, in three patients the diameter of the infragenual segment of the vein turned out to be too small to be used as a bypass conduit. In these cases the GSV of the contralateral lower leg, the small saphenous vein of the contralateral lower leg and a prosthetic graft were used respectively to complement the supragenual GSV in order to acquire a bypass conduit which is long enough. This observation does not hamper the validity or significance of our results but retrospectively highlights that an extension of our preoperative mapping to the infragenual GSV could have presented useful additional information for the surgeons.
In conclusion, the MR-angiographic assessment of the suitability of the saphenous vein as a bypass conduit corresponded with the sonographic evaluation in all of the patients who underwent peripheral MRA and subsequent bypass surgery. With BPCA-MRA, a reliable assessment of the venous diameter of the GSV is possible and shows no significant differences in comparison to DUS as the standard of reference. Consequently, in patients with PAOD who in the preoperative workup undergo peripheral MRA to evaluate the arterial status, the inherent MR-angiographic imaging of autogenous saphenous veins can offer additional information regarding the suitability of the veins as a bypass conduit without the need of an additive ultrasound examination.
Supporting Information
Funding Statement
These authors have no support or funding to report.
References
- 1. Chaikhouni A (2010) The magnificient century of cardiothoracic surgery. Heart Views 11: 31–37. [PMC free article] [PubMed] [Google Scholar]
- 2.Twine CP, McLain AD (2010) Graft type for femoro-popliteal bypass surgery. Cochrane Database Syst Rev CD001487. doi:10.1002/14651858.CD001487.pub2. [DOI] [PubMed]
- 3. Klinkert P, Post PN, Breslau PJ, van Bockel JH (2004) Saphenous vein versus PTFE for above-knee femoropopliteal bypass. A review of the literature. Eur J Vasc Endovasc Surg 27: 357–362. [DOI] [PubMed] [Google Scholar]
- 4. Schanzer A, Hevelone N, Owens CD, Belkin M, Bandyk DF, et al. (2007) Technical factors affecting autogenous vein graft failure: observations from a large multicenter trial. J Vasc Surg 46: 1180–1190. [DOI] [PubMed] [Google Scholar]
- 5. Burnand KG, Senapati A, Thomas ML, Browse NL (1985) A comparison of preoperative long saphenous phlebography with operative dissection in assessing the suitability of long saphenous vein for use as a bypass graft. Ann R Coll Surg Engl 67: 183–186. [PMC free article] [PubMed] [Google Scholar]
- 6. Mosley JG, Manhire AR, Raphael M, Marston JA (1983) An assessment of long saphenous venography to evaluate the saphenous vein for femoropopliteal bypass. Br J Surg 70: 673–674. [DOI] [PubMed] [Google Scholar]
- 7. Shah DM, Chang BB, Leopold PW, Corson JD, Leather RP, et al. (1988) The anatomy of the greater saphenous venous system. J Vast Surg 3: 273–283. Tabrisky J, Christie SG, Nejdl RJ, Lindstrom RR (1976) The value of preoperative saphenous venography for graft evaluation in femoral arterial occlusive disease. J Can Assoc Radiol 27: 37–44. [PubMed] [Google Scholar]
- 8. Veith F, Moss C, Sprayregen S, Montefusco C (1979) Preoperative saphenous venography in arterial reconstructive surgery of the lower extremity. Surgery 85: 253–256. [PubMed] [Google Scholar]
- 9. Leopold PW, Shandall AA, Corson JD, Shah DM, Leather RP, et al. (1986) Initial experience comparing B-mode imaging and venography of the saphenous vein before in situ bypass. Am J Surg 152: 206–210. [DOI] [PubMed] [Google Scholar]
- 10. McShane MD, Field J, Smallwood J, Chant AD (1988) Early experience with B mode ultrasound mapping of the long saphenous vein prior to femorodistal bypass. Ann R Coll Surg Engl 70: 147–149. [PMC free article] [PubMed] [Google Scholar]
- 11. Buchbinder D, Semrow C, Friedell ML, Ryan T, Calligaro K, et al. (1987) B- mode ultrasonic imaging in the preoperative evaluation of saphenous vein. Am Surg 53: 368–372. [PubMed] [Google Scholar]
- 12. Luckraz H, Lowe J, Pugh N, Azzu AA (2008) Pre-operative long saphenous vein mapping predicts vein anatomy and quality leading to improved post-operative leg morbidity. Interact Cardiovasc Thorac Surg 7: 188–191. [DOI] [PubMed] [Google Scholar]
- 13. Lemmer JH, Meng RL, Corson JD, Miller E (1988) Preoperative saphenous vein mapping for coronary artery bypass. J Card Surg 3: 237–240. [DOI] [PubMed] [Google Scholar]
- 14. Head HD, Brown MF (1995) Preoperative vein mapping for coronary artery bypass operations. Ann Thor Surg 59: 144–148. [DOI] [PubMed] [Google Scholar]
- 15. Seeger JM, Schmidt JH, Flynn TC (1987) Preoperative saphenous and cephalic vein mapping as an adjunct to reconstructive arterial surgery. Ann Surg 205: 733–739. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16. Leopold PW, Shandall A, Kupinski AM, Chang BB, Kaufman J, et al. (1989) Role of B-mode venous mapping in infrainguinal in situ veinarterial bypasses. Br J Surg 76: 305–307. [DOI] [PubMed] [Google Scholar]
- 17. Towne JB, Schmitt DD, Seabrook GR, Bandyk DF (1991) The effect of vein diameter on patency of in situ grafts. J Cardiovasc Surg 32: 192–196. [PubMed] [Google Scholar]
- 18. Wengerter KR, Veith FJ, Gupta SK, Ascer E, Rivers SP (1990) Influence of vein size (diameter) on infrapopliteal reversed vein graft patency. J Vasc Surg 11: 525–531. [DOI] [PubMed] [Google Scholar]
- 19. Puppinck P, Habi K, Ducasse E, Espagne P (1997) Evaluation of the venous network before arterial revascularization surgery. J Mal Vasc 22: 162–167. [PubMed] [Google Scholar]
- 20. Collins R, Cranny G, Burch J, Aguiar-Ibáñez R, Craig D, et al. (2007) A systematic review of duplex ultrasound, magnetic resonance angiography and computed tomography angiography for the diagnosis and assessment of symptomatic, lower limb peripheral arterial disease. Health Technol Assess 11: 1–184. [DOI] [PubMed] [Google Scholar]
- 21. Lenhart M, Finkenzeller T, Paetzel C, Strotzer M, Mann S, et al. (2002) Contrast-enhanced MR angiography in the routine work-up of the lower extremity arteries. Rofo 174: 1289–1295. [DOI] [PubMed] [Google Scholar]
- 22. Ruehm SG, Goyen M, Debatin JF (2002) MR angiography: first choice for diagnosis of the arterial vascular system. Rofo 174: 551–561. [DOI] [PubMed] [Google Scholar]
- 23. Kroft LJ, de Roos A (1999) Blood pool contrast agents for cardiovascular MR imaging. J Magn Reson Imaging 10: 395–403. [DOI] [PubMed] [Google Scholar]
- 24. Klessen C, Hein PA, Huppertz A, Voth M, Wagner M, et al. (2007) Firstpass whole-body magnetic resonance angiography (MRA) using the blood-pool contrast medium gadofosveset trisodium: comparison to gadopentetate dimeglumine. Invest Radiol 42: 659–664. [DOI] [PubMed] [Google Scholar]
- 25. Maki JH, Wang M, Wilson GJ, Shutske MG, Leiner T (2009) Highly accelerated first- pass contrast-enhanced magnetic resonance angiography of the peripheral vasculature: comparison of gadofosveset trisodium with gadopentetate dimeglumine contrast agents. J Magn Reson Imaging 30: 1085–1092. [DOI] [PubMed] [Google Scholar]
- 26. Frydrychowicz A, Russe MF, Bock J, Stalder AF, Bley TA, et al. (2010) Comparison of gadofosveset trisodium and gadobenate dimeglumine during time- resolved thoracic MR angiography at 3T. Acad Radiol 17: 1394–1400. [DOI] [PubMed] [Google Scholar]
- 27. Lauffer RB, Parmelee DJ, Dunham SU, Ouellet HS, Dolan RP, et al. (1998) MS-325: albumin-targeted contrast agent for MR angiography. Radiology 207: 529–538. [DOI] [PubMed] [Google Scholar]
- 28. Grist TM, Korosec FR, Peters DC, Witte S, Walovitch RC, et al. (1998) Steady-state and dynamic MR angiography with MS-325: initial experience in humans. Radiology 207: 539–544. [DOI] [PubMed] [Google Scholar]
- 29. Goyen M (2008) Gadofosveset-enhanced magnetic resonance angiography. Vasc Health Risk Manag 4: 1–9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30. Hadizadeh DR, Gieseke J, Lohmaier SH, Wilhelm K, Boschewitz J, et al. (2008) Peripheral MR angiography with blood pool contrast agent: prospective intraindividual comparative study of high-spatial-resolution steady-state MR angiography versus standard-resolution first-pass MR angiography and DSA. Radiology 249: 701–711. [DOI] [PubMed] [Google Scholar]
- 31. Pfeil A, Betge S, Poehlmann G, Boettcher J, Drescher R, et al. (2012) Magnetic resonance VIBE venography using the blood pool contrast agent gadofosveset trisodium-An interrater reliability study. Eur J Radiol 81: 547–552. [DOI] [PubMed] [Google Scholar]
- 32. Hoffmann U, Loewe C, Bernhard C, Weber M, Cejna M, et al. (2002) MRA of the lower extremities in patients with pulmonary embolism using a blood pool contrast agent: initial experience. J Magn Reson Imaging 15: 429–437. [DOI] [PubMed] [Google Scholar]
- 33. Aschauer M, Deutschmann HA, Stollberger R, Hausegger KA, Obernosterer A, et al. (2003) Value of a blood pool contrast agent in MR venography of the lower extremities and pelvis: preliminary results in 12 patients. Magn Reson Med 50: 993–1002. [DOI] [PubMed] [Google Scholar]
- 34. Hadizadeh DR, Kukuk GM, Fahlenkamp UL, Pressacco J, Schäfer C, et al. (2012) Simultaneous MR arteriography and venography with blood pool contrast agent detects deep venous thrombosis in suspected arterial disease. AJR Am J Roentgenol 198: 1188–1195. [DOI] [PubMed] [Google Scholar]
- 35. Hartmann M, Wiethoff AJ, Hentrich HR, Rohrer M (2006) Initial imaging recommendations for Vasovist angiography. Eur Radiol 16 Suppl 2: B15–B23. [DOI] [PubMed] [Google Scholar]
- 36. Goyen M (2007) Gadofosveset: the first intravascular contrast agent EU-approved for use with magnetic resonance angiography. Future Cardiol 3: 19–26. [DOI] [PubMed] [Google Scholar]
- 37. Perreault P, Edelman MA, Baum RA, Yucel EK, Weisskoff RM, et al. (2003) MR angiography with gadofosveset trisodium for peripheral vascular disease: phase II trial. Radiology 229: 811–820. [DOI] [PubMed] [Google Scholar]
- 38. Prandoni P (2007) Links between arterial and venous disease. J Intern Med 262: 341–350. [DOI] [PubMed] [Google Scholar]
- 39. Cohn JD, Korver KF (2005) Optimizing saphenous vein site selection using Intraoperative venous duplex ultrasound scanning. Ann Thorac Surg 79: 2013–2017. [DOI] [PubMed] [Google Scholar]
- 40. van Dijk LC, Wittens CH, Pieterman H, van Urk H (1996) The value of pre-operative ultrasound mapping of the greater saphenous vein prior to ‘closed’ in situ bypass operations. Eur J Radiol 23: 235–237. [DOI] [PubMed] [Google Scholar]
- 41. Goyen M, Shamsi K, Schoenberg SO (2006) Vasovist-enhanced MR angiography. Eur Radiol 16 Suppl 2: B9–14. [DOI] [PubMed] [Google Scholar]
- 42. Cowper SE, Robin HS, Steinberg SM, Su LD, Gupta S, et al. (2000) Scleromyxoedema-like cutaneous diseases in renal-dialysis patients. Lancet 356: 1000–1001. [DOI] [PubMed] [Google Scholar]
- 43. Grobner T (2006) Gadolinium–a specific trigger for the development of nephrogenic fibrosing dermopathy and nephrogenic systemic fibrosis? Nephrol Dial Transplant 21: 1104–1108. [DOI] [PubMed] [Google Scholar]
- 44. Marckmann P, Skov L, Rossen K, Dupont A, Damholt MB, et al. (2006) Nephrogenic systemic fibrosis: suspected causative role of gadodiamide used for contrast-enhanced magnetic resonance imaging. J Am Soc Nephrol 7: 2359–2362. [DOI] [PubMed] [Google Scholar]
- 45. Breitschaft A, Stahlmann R (2009) Nephrogenic systemic fibrosis. Med Monatsschr Pharm 32: 377–382. [PubMed] [Google Scholar]
- 46. Braverman IM, Cowper S (2010) Nephrogenic systemic fibrosis. F1000 Med Rep 2: 84. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 47. Anzidei M, Napoli A, Marincola BC, Nofroni I, Geiger D, et al. (2009) Gadofosveset-enhanced MR angiography of carotid arteries: does steady-state imaging improve accuracy of first-pass imaging? Comparison with selective digital subtraction angiography. Radiology 251: 457–466. [DOI] [PubMed] [Google Scholar]
- 48. Bonel HM, Saar B, Hoppe H, Keo HH, Husmann M, et al. (2009) MR angiography of infrapopliteal arteries in patients with peripheral arterial occlusive disease by using Gadofosveset at 3.0 T: diagnostic accuracy compared with selective DSA. Radiology 253: 879–890. [DOI] [PubMed] [Google Scholar]
- 49. Kos S, Reisinger C, Aschwanden M, Bongartz GM, Jacob AL, et al. (2009) Pedal angiography in peripheral arterial occlusive disease: first-pass i.v. contrast- enhanced MR angiography with blood pool contrast medium versus intraarterial digital subtraction angiography. AJR Am J Roentgenol 192: 775–784. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.