Skip to main content
. Author manuscript; available in PMC: 2015 Nov 1.
Published in final edited form as: Am J Ophthalmol. 2014 Jul 29;158(5):999–1007.e1. doi: 10.1016/j.ajo.2014.07.034

Table 2.

Time Implications for Performing Intraoperative Optical Coherence Tomography During Ophthalmic Surgery with a Microscope Mounted System.

Overall Anterior Posterior
Scan sessions, median (range) 2 (1–5) 2 (1–4) 2 (1–5)
Total scans, median (range) 6 (1–24) 4 (1–14) 10 (1–24)
Time to 1st image after pausing surgery, median (range), minutes 1.7 (0.3–12.4) 1.6 (0.3–12.4) 1.7 (0.6–7.1)
Total duration surgery paused for intraoperative OCT imaging, median (range), minutes 4.9 (0.4–26.7) 3.2 (0.4–17.8) 6.6 (1.0–26.7)
Median duration surgery paused for intraoperative OCT imaging per scan session 2.8 minutes 1.9 minutes 3.4 minutes