Figure 4. Reversibility of the temperature-dependent effect on TR-FRET signal.

Figure 4

Following assembly of the TR-FRET cocktail (2B7-Tb and MW1-d2, 1∶10 ratio), the same samples were subjected to 2 successive cycles of incubation (for 1 hr) and measurement, at the two different temperatures (RT and 4°C). Note that the difference between fluorescence ratio values obtained at RT or 4°C is inversely correlated with polyQ length. A-F. Reversibility for HTT N548 HTT of increasing polyQ length (Q16, Q19, Q25, Q33, Q39, Q55). G. Correlation between fluorescence ratio values obtained in the two RT readings performed during the cycles. H. Correlation between fluorescence ratio values obtained in the two 4°C readings performed during the cycles.