Table 2. Experimental design matrix to screen important variables for extraction yields of AG and DHQ.
Run | Factor A | Factor B | Factor C | Response Y1 | Response Y2 |
Extraction time (min) | Ultrasound power (W) | Solid-liquid ratio (g/mL) | Extraction yield of DHQ (mg/g) | Extraction yield of AG (mg/g) | |
1 | 40 | 250 | 1∶18 | 36.1 | 163.4 |
2 | 50 | 150 | 1∶16 | 34.2 | 154.3 |
3 | 50 | 250 | 1∶20 | 36.9 | 183.2 |
4 | 60 | 200 | 1∶20 | 37.1 | 185.4 |
5 | 40 | 200 | 1∶20 | 36.3 | 169.5 |
6 | 60 | 250 | 1∶18 | 36.6 | 179.7 |
7 | 40 | 200 | 1∶16 | 36.2 | 161.7 |
8 | 50 | 200 | 1∶18 | 36.7 | 183.4 |
9 | 50 | 200 | 1∶18 | 36.8 | 183.2 |
10 | 50 | 150 | 1∶20 | 35.6 | 158.3 |
11 | 60 | 150 | 1∶18 | 35.1 | 160.2 |
12 | 40 | 150 | 1∶18 | 34.5 | 156.8 |
13 | 50 | 200 | 1∶18 | 36.7 | 183.8 |
14 | 50 | 200 | 1∶18 | 36.9 | 183.5 |
15 | 50 | 200 | 1∶18 | 36.7 | 183.1 |
16 | 60 | 200 | 1∶16 | 36.0 | 163.3 |
17 | 50 | 250 | 1∶16 | 36.5 | 176.7 |