Skip to main content
. 2014 Dec 8;9(12):e110433. doi: 10.1371/journal.pone.0110433

Table 2. The proportion of biting mosquitoes in the presence of 0.03% Transfluthrin coils placed as a point source at different distances.

Distance Control Treatment 95% CI z Value p Value Odds ratio
0.3 m 257/400(0.65) 80/400(0.20) [0.12–0.31] −12.206 <0.001 0.14
1 m 167/400(0.41) 88/400(0.21) [0.12–0.31] −6.153 <0.001 0.39
5 m 177/400(0.44) 114/400(0.28) [0.18–0.41] −4.709 <0.001 0.50
10 m 394/400(0.90) 274/440(0.63) [0.49–0.75] −9.017 <0.001 0.19
15 m 344/440(0.79) 252/440(0.57) [0.43–0.71] −6.595 <0.001 0.37
20 m 347/440(0.80) 273/400(0.63) [0.48–0.75] 5.535 <0.001 0.44
30 m 147/400(0.33) 156/400(0.36) [0.24–0.50] 0.713 0.476 1.10

CI-Confidence intervals; the values placed in brackets in the control and treatment columns are model estimated mean proportions.