LLLT preconditioning and exercise: experimental animal models (adapted from Ferraresi et al 2012).

Ref Light source/Wavelength Spot area (cm2) Performance characteristics Muscle(s) Exercise
Lopes-Martins et al, 2006a Laser 655 nm 0.08
  • - 2.5 mW; 31.25 mW/cm2

  • - 1 application point

  • - Groups: 0.5 J/cm2(32 s) / 1 J/cm2 (80 s) / 2.5 J/cm2(160 s)

Tibialis anterior Neuromuscular electric stimulation
Leal Junior et al, 2009c Laser 904 nm 0.2
  • - 15 mW, 75 mW/cm2

  • - 1 application point

  • - Groups: 0.1 J (7 s) / 0.3 J (20 s) / 1 J (67 s) / 3 J (200 s)

Tibialis anterior Neuromuscular electric stimulation
de Almeida et al, 2011 Laser 904 nm 0.2
  • - 15 mW; 75mW/cm2

  • - 1 application point

  • - Groups: 0.1 J (7 s) / 0.3 J (20 s) / 1 J (67 s) / 3 J (200 s)

Tibialis anterior Neuromuscular electric stimulation