Reference MR Specifications Acquisition Voxel Size (mm) Reconstruction Voxel Size (mm) No. Directions Duration of DTI Software Package Used for DTI Pre/Post Processing and Analysis Number of ROIs
Adamson et al. (2013) 3T Philips Medical Systems scanner Echoplanar imaging sequence: TR = 8799ms; TE = 88ms; flip angle = 90°; slice thickness = 2mm; 72 contiguous slices; FOV = 180 × 180 mm2; b = 1000s/mm2 33   FMRIB Software Library (TBSS, FNIRT) Whole brain
Borich et al. (2013)/ Virji-Babul et al. (2013) 3T Philips Achieva Single shot echoplanar imaging sequence; TR = 7013ms; TE = 60ms; FOV = 224 × 224mm; 70 slices; voxel dimension = 2.23; b = 700s/mm2 60 7 mins ExploreDTI Left and right anterior corona radiata, left and right thalamic radiation, right forceps minor, right inferior longitudinal fasciculus, right and left inferior fronto-occipital fasciculus, fornix, left subcallosal cortex, right thalamus, genu CC
Caeyenberghs et al. (2010/2011) 3T Phillips Intera with 8-channel head coil Diffusion weighted single shot spin-echo echoplanar imaging with data acquisition matrix = 112 × 112; FOV = 220 × 220 mm2; TR = 7916 ms, TE = 68 ms, parallel imaging factor 2.5, and 68 contiguous sagittal slices (slice thickness = 2.2 mm; voxel size = 2 × 2 × 2.2 mm3) 45   ExploreDTI Corpus callosum, corticospinal tract, superior cerebellar peduncle, inferior cerebellar peduncle, cerebral peduncle, anterior corona radiate, ALIC, PLIC
Chu et al. (2010)/ Wu, et al. (2010)a Yallampalli et al. (2010)/ Wilde et al. (2008) 3T Philips Achieva Transverse multi-slice spin-echo single shot echoplanar imaging sequence; FOV = 256 mm; TR = 6318 ms; TE = 51 ms; 70 slices, slice thickness = 2 mm, 0 mm gap; b = 0, and 1000 s/mm2 30 5 mins Philips PRIDE registration tool and DTIStudio Right and left cingulumbundle, fornix, total CC, 3 tissue masks: White Matter, Grey Matter, and CerebroSpinal Fluid used in regional analyses of whole brain
Ewing-Cobbs et al. (2008) 3T Philips Intera Single shot spin-echo diffusion sensitized echoplanar imaging; FOV = 240 × 240 mm2; TR = 6100 ms; TE = 84 ms; b = 1000 s/mm2; slice thickness = 3 mm with 44 axial slices   7 mins In-house-developed DTI design and analysis toolbox Rostrum, renu, rostral midbody, anterior midbody, posterior midbody, isthmus, and splenium of the corpus callosum
Johnson et al. (2011) 3T Philips scanner with 8-channel head coil Single shot spin-echo diffusion sensitized echoplanar imaging sequence; FOV = 240 × 240 mm2; TR = 6100 ms; TE = 84 ms; b = 0, and 1000 s/mm2; matrix = 256 x 256; slice thickness = 3 mm 21 7 mins Freesurfer v4.1.0 software and FMRIB Software Library (FLIRT) Uncinate fasciculus
Juranek et al. (2012) 3T Philips scanner with 8-channel phase array head coil Single shot spin-echo diffusion sensitized echoplanar imaging sequence; FOV = 240 × 240 mm2; TR = 6100 ms; TE = 84 ms; b = 0, and 1000 s/mm2; matrix = 256 × 256; slice thickness = 3 mm 21 7 mins Freesurfer v4.0.5 software and FMRIB Software Library (BET, FLIRT, DTIFIT) Amygdala, hippocampus
Kurowski et al. (2009)/ Yuan et al. (2007) 3T Siemens Trio Single shot spin-echo echoplanar imaging sequence; FOV = 25.6 × 25.6 cm2; TR = 6000 ms; TE = 87 ms; b = 1000 s/mm2; matrix = 128 × 128; slice thickness = 2 mm with 46 axial slices 12 5:48 mins DTIStudio 2.4 from John Hopkins University Splenium of the corpus callosum, genu of the corpus callosum, body of the corpus callosum, ALIC, PLIC, inferior fronto-occipital fasciculus, superior longitudinal fasciculus, left frontal white matter, right frontal white matter
Levin et al. (2008) 1.5T Philips Integra Transverse multi-slice spin-echo single shot echoplanar imaging sequence; FOV = 256 mm; TR = 10150.5 ms; TE = 90 ms; slice thickness = 2.7 mm, 0 mm gap; b = 0, and 860s/mm2 15 5:45 mins Philips diffusion affine registration tool and Philips fiber tracking 4.1V3 Beta 4 software Corpus callosum, genu CC, body CC, splenium CC, ALIC, PLIC, frontal lobes (ventromedial, dorsolateral), temporal lobes
Levin et al. (2011) 1.5T Philips scanner Transverse multi-slice spin-echo single shot echoplanar imaging sequence; FOV = 256 mm; TR = 10150.5 ms; TE = 90 ms; slice thickness = 2.7 mm; b = 860 s/mm2 15 5:45 mins Philips diffusion affine registration tool and Philips fiber tracking 4.1 V3 Beta 4 software Corpus callosum, prefrontal white matter, uncinate fasciculus, inferior longitudinal fasciculus, cingulum bundle, frontal lobes, temporal lobes
Max et al. (2012) 1.5T Philips Intera Transverse multi-slice spin-echo single shot echolpanar imaging sequence; FOV = 256mm; TR = 10150.5ms; TE = 90 ms; slice thickness = 2.7 mm, 0 mm gap; b = 2, and 860 s/mm2 15 6 mins Philips PRIDE registration tool and Philips fiber tracking 4.1v3 Beta 2 software Right and left frontal lobe, right and left uncinate fasciculi, right and left centrum semiovale, and right and left temporal lobes
Mayer et al. (2012) 3T Siemens Gradient echo sequence; FOV = 180x240 mmTR = 28ms; TE = 20ms; flip angle = 15°; slice thickness = 1.5mm, 88 slices; b = 0 and 860 mm230 30   FMRIB Software Library (TBSS, FNIRT) and Automated Functional Neuro-Imaging (AFNI) Left and right anterior corona radiata, left white matter tracts, left cerebral peduncle, left superior corona radiata
McCauley et al. (2011) 1.5T Philips Intera Transverse multi-slice spin-echo single shot echoplanar imaging sequence; FOV = 256 mm; TR = 10150.5 ms; TE = 90 ms; slice thickness = 2.7 mm, 0 mm gap; b = 0, and 860 s/mm2 15 5:45 mins Philips PRIDE registration tool and Philips fiber tracking 4.1v3 Beta 2 software Cingulum bundle, orbitofrontal white matter, uncinate fasciculus
Oni et al. (2010)/ Wilde et al. (2010) 1.5T Philips Intera Transverse multi-slice spin-echo single shot echoplanar imaging sequence; FOV = 256 mm; TR = 10150.5 ms; TE = 90 ms; slice thickness = 2.7 mm, 0 mm gap; b = 0, and 860 s/mm2 15 5:45 mins Philips diffusion affine registration tool and Philips fiber tracking 4.1V3 Beta 4 software Left and right frontal lobes, left and right cingulum bundle
Schiebel et al. (2011) 3T Philips Achieva Transverse multi-slice spin-echo single shot echoplanar imaging sequence; FOV = 224 mm; TR = 6161 ms; TE = 51 ms; slice thickness = 2 mm, 0 mm gap; b = 0, and1000 s/mm2 32 5 mins Philips diffusion affine registration tool and Philips fiber tracking 4.1V3 Beta 4 software Ventromedial and dorsolateral frontal regions, arcuate fasciculus, inferior fronto-occipital fasciculus, inferior longlitudinal fasciculus, uncinate fasciculus, corpus callosum, cingulum bundle, ALIC, PLIC
Schmidt et al. (2013) 1.5T Philips Intera Transverse multi-slice spin-echo single shot echolpanar imaging sequence; FOV = 256mm; TR = 10150.5ms; TE = 90 ms; slice thickness = 2.7 mm, 0 mm gap; b = 0, and 860 s/mm2 15   Philips PRIDE registration tool and Philips fiber tracking 4.1v3 Beta 2 software Right and left inferior left longitudinal fasciculus, right and left uncinated fasciculus
Wilde et al. (2005/2006) 1.5T Philips Intera Transverse multi-slice spin-echo single shot echoplanar imaging sequence; FOV = 256 mm; TR = 10150.5 ms; TE = 90 ms; slice thickness = 2.7 mm, 0 mm gap; b = 0, and 860 s/mm2 15 5:45 mins Philips PRIDE registration tool and Philips Fiber Tracking 4.1V3 software Genu CC, body CC, splenium CC, anterior commissure
Wilde et al. (2011) 3T Philips Intera Transverse multi-slice spin-echo single shot echoplanar imaging sequence; FOV = 224 mm; TR = 6161 ms; TE = 51 ms; slice thickness = 2 mm, 0 mm gap; b = 0, and 1000 s/mm2 30 5:45 mins Philips PRIDE registration tool and Philips fiber tracking 4.1v3 Beta 2 software Inferiorfronto-occipital fasciculus, inferior longitudinal fasciculus, frontal white matter, uncinate fasciculus, ALIC, PLIC, cingulum bundle
Wozniak et al. (2007) 3T Siemens Trio Dual spin echo, single shot, pulsed gradient, echoplanar imaging sequence; FOV = 256 mm; TR = 8300 ms; TE = 86 ms; 64 slices; b = 1000 s/mm2 12   FMRIB Software Library (BET, FLIRT, FAST, FUGUE, FDT) Inferior frontal mask, superior frontal mask, supracallosal mask, genu CC, midbody CC, splenium CC
Wu, Wilde, Bigler, Li, et al. (2010) 1.5T Philips Intera Transverse multi-slice spin-echo single shot echoplanar imaging sequence; FOV = 256 mm; TR = 10150.5 ms; TE = 90 ms; 55 slices, slice thickness = 2.7 mm, 0 mm gap; b = 0, and 860 s/mm2 15 6 mins Philips PRIDE registration tool and Philips fiber tracking 4.1v3 Beta 2 software Genu CC, body CC, splenium CC, as well as total CC

Note. ROI = region of interest; T = tesla; FOV = field of view; TR = repetition time; TE = echo time; mm = millimetre; ms = millisecond; CC = corpus callosum; ALIC = anterior limb of the internal capsule; PLIC = posterior limb of the internal capsule; MR = magnetic resonance; DTI = diffusion tensor imaging.