Log of strain mode (the ratio of maximum principal to minimum principal strain) during incisor loading in the ex vivo experimental trials and FEA, as measured at four gage sites.

Premaxilla Dorsal rostrum Anterior zygomatic Palate
Incisor trial 1 −0.6558 −0.6480 −1.2480 0.4210
Incisor trial 2 −0.5687 −0.6247 −0.7637 0.4187
Incisor trial 3 −0.5387 −0.5684 −0.4762 0.4870
Incisor trial 4 −0.6399 −0.7458 −0.5852 0.5342
Ex vivo mean (s.d.) −0.601 (0.056) −0.647 (0.074) −0.768 (0.341) 0.465 (0.056)
FEA −0.43 −0.39 −0.01 0.1