Skip to main content
. 2014 Dec 4;2014:830649. doi: 10.1155/2014/830649

Table 2.

Overall performance of difference and accuracy between 24 h-CrCl and estimated GFR.

Equations Mean of difference ± SD  
(mL/min)
R 2 Accuracy within
15% 30% 50%
Cockcroft-Gault 2.3 ± 20.2 0.49 46 69 88
MDRD −18.8 ± 26.9 0.28 25 44 72
CKD-EPI −9.1 ± 22.9 0.30 33 56 75