Skip to main content
. 2014 Nov 26;30(12):1597–1613. doi: 10.1002/cnm.2691

Table 3.

Average regional stress and strain along the fibre direction on the three local regions defined in Figure 9 when the mitral valve is fully opened, just closed, and fully loaded with peak systolic pressure.

Stress along fibre directions (kPa) Strain along fibre directions
Regions Fully-opened Just-closed Fully-loaded Fully-opened Just-closed Fully-loaded
Trigon 1 −2.9 92 193 −0.004 0.04 0.04
Trigon 2 −0.8 72 144 −0.004 0.02 0.02
The belly region 17 79 142 0.04 0.02 0.02