Skip to main content
. 2014 Jun 9;26(9):1256–1265. doi: 10.1111/nmo.12382

Table 2.

Accuracy of the EAT-10 in detecting dysphagia, impaired efficacy and safety of swallow, and aspirations at the normative cut-off 3

EAT-10 ≥ 3
Sensitivity (95% CI) Specificity (95% CI) PPV NPV LHR+ LHR−
OD 0.85 (0.77–0.91) 0.82 (0.57–0.96) 0.828 0.847 4.72 0.183
Impaired efficacy 0.88 (0.80–0.94) 0.59 (0.41–0.76) 0.684 0.830 2.15 0.203
Impaired safety 0.87 (0.79–0.93) 0.68 (0.46–0.85) 0.731 0.837 3.13 0.191
Aspirations 0.83 (0.61–0.95) 0.25 (0.17–0.34) 0.525 0.592 1.11 0.680

CI, simultaneous confidence interval; PPV, positive predictive value; NPV, negative predictive value; LHR, likelihood ratio; OD, oropharyngeal dysphagia.