Table 4.
Comparisons between CT-defined lung density-based and SPECT lung perfusion-based correlations with the changes in PFTs
Methods | No. of tests | r | p-value | p-value* | |
---|---|---|---|---|---|
DLCO | SPECT-based | 141 | 0.26 | 0.002 | 0.25 |
CT-based | 141 | 0.34 | <0.001 | ||
FEV1 | SPECT-based | 141 | 0.33 | <0.001 | 0.23 |
CT-based | 141 | 0.41 | <0.001 |
Comparisons between correlation coefficients for CT- and SPECT-based comparisons
Abbreviations: SPECT = single photon emission computed tomography; CT = computed tomography; other abbreviations as in Table 2.