Table 3.
Dilatation methods | |
Balloon dilation | Graded dilation |
Radial force leads to bigger neo-tract diameter (easier but greater risk for bile leakage, bleeding and perforation) | Axial force creates a smaller neo-tract. More difficult, but less leakage and less bleeding) |
Easier stent insertion | Stent insertion can be more difficult |
Only a single dilation session is needed and there are fewer guidewire exchanges | More sessions of dilation are needed and there are more frequent guidewire exchanges |