Table 3.

The CD (Cones/deg2) Measured From a Subset of Images Where the Identification of Every Single Cone was Possible Within One ROI

Subject
Eye
ROI
CD
Grader 1
Grader 2
40058 OS N3-4 3712 3802 3695
40058 OD T5-6 2256 2473 2307
40060 OS N2 3392 3522 3501
40060 OD N5 1936 1948 1835
30015 OS T3 3488 3829 3868
30015 OD T5 2448 2147 1999

Columns 5 (Grader 1) and 6 (Grader 2) show the cone density values converted from cone spacing measures, assuming a hexagonal pattern at similar retinal eccentricity. Column 3 shows the retinal location, where N stands for nasal and T for temporal. N2 is located at 1.0° nasal to the fovea, and subsequent ROIs are separated by 0.5° spacing intervals as described in the Materials and Methods.