Young mice (17 wk) contractility and LV chamber dimensions by M-mode and tissue Doppler echocardiography

Ntg TgcTnIP82S
n 8 9
HR, beats/min 711 ± 12 688 ± 5
LVEDD, mm 2.94 ± 0.05 2.93 ± 0.04
LVESD, mm 1.14 ± 0.03 1.12 ± 0.03
FS, % 61.3 ± 0.15 69.9 ± 0.55
IVCT, ms 16.43 ± 0.15 17.67 ± 0.13
ET, ms 43.71 ± 0.25 43.33 ± 0.2
IVRT, ms 19.29 ± 0.18 20.33 ± 0.15
Tei index 0.82 ± 0.04 0.88 ± 0.03
Ea, cm/s 0.06 ± 0.003 0.09 ± 0.015
Aa, cm/s 0.05 ± 0.004 0.06 ± 0.011
Ea/Aa ratio 1.45 ± 0.1 1.36 ± 0.1
LV mass 91.5 ± 3.27 95.99 ± 4.68

Values are averages ± SE; n, no. of mice.

LV mass = 1.055 × [(IVSD + LVEDD + LVPWTED)3] − (LVEDD)3, where IVSD is interventricular septal thickness at end-diastole, and LVPWTED is LV posterior wall thickness at end diastole.

*