Table 1.
Connection tested | Incidence | Synaptic strength (pA) | Delay time (ms) |
---|---|---|---|
HVC(RA) → INT (E, m) | 34/43 | 135.6 ± 155.8 | 0.43 ± 0.16 |
INT → HVC(RA) (I, m) | 28/42 | 31.8 ± 28.0 | 0.37 ± 0.10 |
HVC(RA) → HVC(RA) (E, m) | 1/140 | 22.8 | 1.01 |
HVC(RA) → HVC(RA) (I, d) | 78/140 | 25.2 ± 23.8 | 1.85 ± 0.30 |
Values for incidence, average synaptic strength measured in voltage clamp, and delay times are shown for all paired recordings. The type of connection is shown on the right in the first column: E, Excitatory; I, inhibitory; m, monosynaptic; d, disynaptic.