Summary of previous studies using positron emission tomography/computed tomography for the diagnosis of musculoskeletal tumors.

Study, year (Refs.) No. of patients SUVmax SUVmax cut off Sensitivity, % Specificity, % Accuracy, %

Benign Malignant
Fuglø 2012 (9) 89 95.8 92.7 93.1
Aoki 2003 (5) 114 1.80 (SD, ±1.42) 4.20 (SD, ±3.16)
Shin 2008 (10) 34 2.9 (range, 0.6–5.5) 12.0 (range, 4.3–45.7) 4.7 89.6 86.7 88.2
Piperkova 2008 (11) 93 100 95.9
Charest 2009 (6) 212 93.9
Iagaru 2006 (12) 44 100 93.3
Strobel (13) 50 3.5 (range, 1.6–8.0) 3.5 ( 1.6–8.0) (range, 1.6–8.0) 91 77 86
Shin 2008 (14) 87 5.1 8.8 4.7 80 63 70
Eary 2002 (15) 209 6 (range, 3.8–11.3)

SD, standard deviation; SUVmax, maximum standardized uptake volume.