TABLE 5.

Summary of Longitudinal Variability for the Centrally Digitized Echocardiographic Measurements Among HIV-Uninfected Children

Measurement Children,
n
Echos,
n
Mean
(Range)
Between-Child Variance Within-Child Variance ICC
Age 6–24 mo
 Fractional shortening, % 325 718 38.3 (25.7–54.8) 8.57 9.55 0.47
 End-diastolic dimension, cm 325 718   2.70 (1.82–3.49) 0.0225 0.0172 0.57
 End-diastolic posterior wall thickness, cm 331 737   0.47 (0.25–0.79) 0.0024 0.0038 0.39
 End-diastolic septal thickness, cm 331 730   0.59 (0.35–1.03) 0.0037 0.0070 0.34
Age 2–6 y
 Fractional shortening, % 167 527 35.9 (26.4–50.2) 6.22 6.11 0.51
 End-diastolic dimension, cm 167 527   3.30 (2.59–4.15) 0.0304 0.0198 0.60
 End-diastolic posterior wall thickness, cm 169 534   0.57 (0.38–0.84) 0.0022 0.0037 0.38
 End-diastolic septal thickness, cm 164 486   0.62 (0.25–1.07) 0.0042 0.0084 0.33