Skip to main content
. 2014 Aug 14;26(2):457–467. doi: 10.1681/ASN.2013101144

Table 2.

Performance of the three assays to predict allograft loss at 1 and 3 years after AMR

Variable C4d Graft Deposition (%) C1q-Binding Assay (%) C3d-Binding Assay (%)
Graft loss at 1 year post-rejection
 Sensitivity 80.0 60.0 90.0
 Specificity 45.5 48.5 51.5
 Positive predictive value 47.1 41.4 52.9
 Negative predictive value 78.9 66.7 89.5
Graft loss at 3 years post-rejection
 Sensitivity 69.2 61.5 84.6
 Specificity 40.0 60.0 73.3
 Positive predictive value 66.7 72.7 84.6
 Negative predictive value 42.9 47.4 73.3