Skip to main content
. Author manuscript; available in PMC: 2015 Jan 29.
Published in final edited form as: Am J Ophthalmol. 2013 Mar 14;155(6):971–982. doi: 10.1016/j.ajo.2013.01.020

Table 7.

Differences in Rate of Rim Area Change in eyes with a Ocular Hypertension Treatment Study Visual Field Primary Open Angle Glaucoma Endpoint compared to eyes with an Optic Disc Primary Open Angle Glaucoma Endpoint only or Optic Disc Change (not necessarily a Primary Open Angle Glaucoma endpoint)

Visual Field and Op.c Disc Change Criteria N (eyes) Slope
(95% CI)
(mm2/yr)
P-Value# P-Value comparing
slopes to VF POAG
Endpoint slope
P-Value comparing
slopes to Not at POAG
endpoint slope
Not at POAG Endpoint 731 −0.0021 (−0.0031, −0.0011) <0.0001 0.1655 NA
Visual Field POAG Endpoint 21 −0.0079 (−0.0157, −0.0001) 0.0513 NA 0.1655
Optic Disc POAG Endpoint Only* 45 −0.0169 (−0.0225, −0.0113) <0.0001 0.0426 0.0001
Optic Disc Reading Center Change (POAG and not POAG)* 72 −0.0131 (−0.0178, −0.0084) <0.0001 0.1433 0.0001
Optic Disc Reading Center Change NOT POAG Endpoint* 27 −0.0094 (−0.0161, −0.0027) 0.0063 0.54 0.0012
*

Does not include the 1 eye that had both a POAG visual field endpoint and a POAG optic disc

#

p-value to evaluate whether the slope is significantly different from zero

POAG: Primary Open Angle Glaucoma