Skip to main content
. 2014 Oct 28;29(2):554–564. doi: 10.1096/fj.14-254953

TABLE 2.

Rod response parameters from single-cell recordings

Idark (pA) I1/2 (phot μm−2) Tpeak (ms) Tintegr (ms) τrec (ms)
Control rods (n = 16) 14.1 ± 0.9 18.1 ± 1.6 255 ± 12 554 ± 20 381 ± 16
STZ rods (n = 16) 13.9 ± 1.0 20.8 ± 3.8 189 ± 11 405 ± 37 284 ± 24
t test NS NS P < 0.0005 P < 0.001 P < 0.005

Experimental parameters: Idark, dark current measured from saturated responses; I1/2, half-saturating light intensity; time to peak (Tpeak) and integration time (Tintegr) refer to responses whose amplitudes were <0.2 Idark and fell within the linear range; τrec, time constant of single-exponential decay of dim flash response recovery phase. STZ, diabetic C57Bl/6J mouse. Values are means ± sem. NS indicates P > 0.05 between control and STZ diabetic rod values.