Skip to main content
. 2015 Feb 4;9:11. doi: 10.3389/fnhum.2015.00011

Table 9.

Summary of TWG conclusions on electrophysiological measures for mTBI detection (0 < 1 < 2 < 3 < 4).

Measure/analysis method History of testing in mTBI patients Usefulness for mTBI detection as a unique entity Usefulness for mTBI detection as part of a discriminant function
Spectral analysis 4 0 2
Connectivity measures 3 1 3
ERPs 4 2 4
Information dynamics 0 Unknowna Unknowna
Symbolic dynamics 2 3 Unknowna
Analysis of casual relationships 2 2 Unknowna
Graph theory 1 3 Unknowna

aUnknown, but high perceived potential.