Skip to main content
. 2015 Jan 22;2015:698310. doi: 10.1155/2015/698310

Table 5.

Serum anti-Dsg 1, serum anti-Dsg3, and salivary antidesmoglein 3 ELISA main diagnostic outcomes using the manufacturer's suggested cut-off value of 20 RU/mL.

Serum anti-Dsg 1 ELISA Serum anti-Dsg 3 ELISA Salivary anti-Dsg 3 ELISA
True positive 62 83 63
True negative 176 176 178
False positive 4 4 2
False negative 24 3 23
Sensitivity 72.09% 96.51% 73.26%
Specificity 97.78% 97.78% 98.89%
Positive predictive values 0.94 0.95 0.97
Negative predictive values 0.88 0.98 0.89
Test accuracy 0.89 0.97 0.91
Positive likelihood ratio 32.44 43.33 65.93
Negative likelihood ratio 0.29 0.04 0.27
Diagnostic odds ratio 113.67 1217.33 243.78
Cohen's kappa coefficient 0.89 0.97 0.90