Skip to main content
. Author manuscript; available in PMC: 2015 Mar 1.
Published in final edited form as: Biomaterials. 2014 Jan 15;35(10):3220–3228. doi: 10.1016/j.biomaterials.2013.12.087

Fig. 6.

Fig. 6

Ectopic bone growth volume for rhBMP-2 carrier system as determined by volumetric analysis of μCT images. (n = 5 animals with bilateral treatment averaging; Mean ± SD; #p < 0.0001 vs ACS).