Testing values and synthetic evaluation index at the design of L9 (23) orthogonal array

Temperature(°C) %dewatering Y1(μmol/g solid) Y2 Y3(kWh/kg) Y4(g/g min) S
50 0 12.380 17.94 8.36 0.734 0.349
50 30 7.400 15.25 7.52 0.692 0.119
50 60 7.920 5.28 5.96 0.801 0.427
60 0 11.720 14.40 5.92 0.914 0.483
60 30 8.611 17.34 4.88 0.748 0.251
60 60 9.408 14.22 3.68 1.538 0.465
70 0 13.330 19.45 7.28 1.134 0.443
70 30 13.740 7.51 5.64 1.118 0.780
70 60 10.930 5.74 2.84 2.159 0.813
0.299 0.425
0.400 0.384
0.679 0.568
0.380 0.185

aA1, A2, A3 are the average values of total evaluation related with the same factor at three levels, respectively

bR = Aimax-Aimin, i = 1,2,3