Skip to main content
. Author manuscript; available in PMC: 2015 Feb 12.
Published in final edited form as: IEEE Trans Neural Syst Rehabil Eng. 2010 Aug;18(4):369–380. doi: 10.1109/TNSRE.2010.2053217

TABLE III.

Evaluation of GMM Systems Based on Different Configurations of Cepstral Feature Extraction.

ECG
ID
number of
cepstra
number of
spectral bands
window length
in second
window shift
in second
first order
delta
HLDA cepstral feature
dimension
GMM Gaussian
components
accuracy
Pc (%)
1 36 64 0.5 0.25 yes no 64 32 55.49
2 36 64 0.25 0.125 yes no 64 32 61.83
3 24 64 0.25 0.125 yes no 48 32 61.45
4 64 64 0.25 0.125 yes no 128 32 57.64
5 24 64 0.25 0.25 yes no 48 32 59.23
6 24 64 0.25 0.125 no no 24 32 59.17
7 24 48 0.12 0.06 yes no 48 16 61.26
8 24 48 0.12 0.06 yes no 48 32 63.20
9 24 48 0.12 0.06 yes no 48 64 63.45
ACC
ID
number of
cepstra
number of
spectral bands
window length
in second
window shift
in second
first order
delta
HLDA cepstral feature
dimension
GMM Gaussian
components
accuracy
Pc (%)
1 20 20 0.48 0.24 yes no 120 32 74.76
2 20 20 0.96 0.48 yes no 120 32 67.48
3 20 20 0.24 0.24 yes no 120 32 70.73
4 20 20 0.48 0.24 yes no 120 16 75.01
5 20 20 0.48 0.24 yes no 120 64 72.45
6 7 20 0.48 0.24 yes no 42 32 72.00
7 20 20 0.48 0.24 yes yes 96 32 77.52
8 20 20 0.48 0.24 yes yes 84 32 77.34
9 20 20 0.48 0.24 yes yes 72 32 77.56

(ACC = Accelerometer)